SKU ADC-T3000

Second-generation Alarm.com thermostat that is a plain Z-Wave Plus S2 device under the branding. Excluded from the dealer's panel and included in Z-Wave JS, Home Assistant drives mode, setpoints, fan, and the humidifier outputs locally with no Alarm.com account in the path.

Works on integrations
Protocols
Setup guides

Built by Building 36 Technologies, which is the manufacturer name Z-Wave JS reports rather than Alarm.com, so do not expect the brand on the box to appear in the Home Assistant device page.

The wiring envelope is what makes it worth keeping: up to 3 stages of heat, 2 stages of cool, heat pump with auxiliary and emergency heat, plus humidifier and dehumidifier outputs and a ventilation stage. That covers most of what a US 24V system will throw at it, and the HVAC type, stage counts, and fuel type are all exposed as Z-Wave configuration parameters, so the commissioning happens in Home Assistant rather than on the panel.

Power it from the C-wire. It will run on 2 AAA cells, but a battery thermostat sleeps, which costs you both responsiveness to setpoint changes and a mains repeater in the middle of the house.

The catch is ownership, not capability. A unit fitted by an Alarm.com dealer is enrolled in the panel’s Z-Wave network, and moving it to Home Assistant means excluding it there first. Once excluded it is gone from the Alarm.com side, so this is a choice between the two systems rather than a way to run both.

Entities in Home Assistant

139 entities via Z-Wave

Primary entities 21 What automations and dashboards use.
EntityTypeDevice classUnit
Battery maintenance statusbinary_sensor——
Hardware statusbinary_sensor——
Low battery levelbinary_sensor——
Mains statusbinary_sensor——
Power statusbinary_sensor——
Software statusbinary_sensor——
Battery maintenance status disabledbutton——
Hardware status disabledbutton——
Power status disabledbutton——
Software status disabledbutton——
Climate (main)climate——
Fan (main) disabledfan——
Humidifier (main)humidifier——
Battery maintenance statussensor——
Hardware statussensor——
Humiditysensor—%
Mains statussensor——
Power statussensor——
Software statussensor——
Temperature fahrenheitsensortemperature°F
Voltagesensor—V
Configuration 117 Settings exposed as entities, tunable from Home Assistant.
EntityTypeDevice classUnit
System configuration: Override disabledbinary_sensor——
Balance Setpoint disablednumber—0.1°F
Battery Alert Threshold Low disablednumber—%
Battery Alert Threshold Very Low disablednumber—%
C-Wire Power Thermistor Offset disablednumber—0.1°F
Calibration Temperature disablednumber—0.1°F
Compressor Delay disablednumber—minutes
Cool Differential disablednumber—0.1°F
Cool Staging Delay disablednumber—minutes
Dehumidify by AC Offset disablednumber—0.1°F
Fan Circulation Duty Cycle disablednumber—%
Fan Circulation Period disablednumber—minutes
Fan Purge Time disablednumber—seconds
Heat Differential disablednumber—0.1°F
Heat Pump Expire disablednumber—minutes
Heat Staging Delay disablednumber—minutes
Humidity Control Swing disablednumber—%
Humidity Reporting Threshold disablednumber—%
Maximum Cool Setpoint disablednumber—0.1°F
Maximum Heat Setpoint disablednumber—0.1°F
Minimum Battery Reporting Interval disablednumber—hours
Minimum Cool Setpoint disablednumber—0.1°F
Minimum Heat Setpoint disablednumber—0.1°F
Number of Cool Stages disablednumber——
Number of Heat Stages disablednumber——
Outdoor Temperature Timeout disablednumber—minutes
Overshoot disablednumber—0.1°F
Remote Temperature ACK Failure Limit disablednumber——
Remote Temperature Differential disablednumber—0.1°F
Remote Temperature Timeout disablednumber—minutes
Swing disablednumber—0.1°F
Temperature Reporting Threshold disablednumber—0.1°F
Vent Circulation Duty Cycle disablednumber—%
Vent Circulation Period disablednumber—minutes
Vent Maximum Outdoor Temperature disablednumber—0.1°F
Vent Minimum Outdoor Temperature disablednumber—0.1°F
Vent Override Lockout disablednumber—hours
Z-Wave Send Fail Limit disablednumber——
Configurable Terminal Setting Z1 disabledselect——
Configurable Terminal Setting Z2 disabledselect——
HVAC Modes Enabled disabledselect——
HVAC System Type disabledselect——
Heat Fuel Type disabledselect——
Humidify Options disabledselect——
Humidity Display disabledselect——
PIR Enable disabledselect——
Relay Harvest Interval disabledselect——
Relay Harvest Level disabledselect——
Remote Temperature Display Enable disabledselect——
Remote Temperature Enable disabledselect——
Run Fan With Auxiliary Heat disabledselect——
Temperature Display Units disabledselect——
Thermostat Lock disabledselect——
Vent Options disabledselect——
Z-Wave Association Report: Ambiant Temperature disabledselect——
Z-Wave Association Report: Battery Low Notification disabledselect——
Z-Wave Association Report: Battery Very Low Notification disabledselect——
Z-Wave Association Report: Display Units disabledselect——
Z-Wave Association Report: HVAC Type disabledselect——
Z-Wave Association Report: Heat Fuel Type disabledselect——
Z-Wave Association Report: Humidity Control Mode disabledselect——
Z-Wave Association Report: Humidity Control Operating State Report disabledselect——
Z-Wave Association Report: Humidity Control Setpoints disabledselect——
Z-Wave Association Report: Notification Report Mains Disconnected disabledselect——
Z-Wave Association Report: Notification Report Mains Reconnected disabledselect——
Z-Wave Association Report: Notification Report Power Applied disabledselect——
Z-Wave Association Report: Notification Report Replace Battery Now disabledselect——
Z-Wave Association Report: Notification Report Replace Battery Soon disabledselect——
Z-Wave Association Report: Notification Report System Hardware Failure disabledselect——
Z-Wave Association Report: Notification Report System Hardware Failure with Code disabledselect——
Z-Wave Association Report: Notification Report System Software Failure disabledselect——
Z-Wave Association Report: Notification Report System Software Failure with Code disabledselect——
Z-Wave Association Report: Number of Cool/Pump Stages disabledselect——
Z-Wave Association Report: Number of Heat/Aux Stages disabledselect——
Z-Wave Association Report: Power Source disabledselect——
Z-Wave Association Report: Relative Humidity disabledselect——
Z-Wave Association Report: Relay Status disabledselect——
Z-Wave Association Report: Remote Enable Report disabledselect——
Z-Wave Association Report: Thermostat Fan Mode disabledselect——
Z-Wave Association Report: Thermostat Fan State disabledselect——
Z-Wave Association Report: Thermostat Mode disabledselect——
Z-Wave Association Report: Thermostat Operating State disabledselect——
Z-Wave Association Report: Thermostat Supported Modes disabledselect——
Z-Wave Echo Association Reports disabledselect——
Current Relay State: B Relay State disabledsensor——
Current Relay State: B Terminal Load disabledsensor——
Current Relay State: C Terminal Load disabledsensor——
Current Relay State: G Relay State disabledsensor——
Current Relay State: G Terminal Load disabledsensor——
Current Relay State: O Relay State disabledsensor——
Current Relay State: O Terminal Load disabledsensor——
Current Relay State: Override Terminal Load disabledsensor——
Current Relay State: RC Relay State disabledsensor——
Current Relay State: RC Terminal Load disabledsensor——
Current Relay State: RH Relay State disabledsensor——
Current Relay State: RH Terminal Load disabledsensor——
Current Relay State: W Relay State disabledsensor——
Current Relay State: W Terminal Load disabledsensor——
Current Relay State: W2 Relay State disabledsensor——
Current Relay State: W2 Terminal Load disabledsensor——
Current Relay State: Y Relay State disabledsensor——
Current Relay State: Y Terminal Load disabledsensor——
Current Relay State: Y2 Relay State disabledsensor——
Current Relay State: Y2 Terminal Load disabledsensor——
Current Relay State: Z1 Relay State disabledsensor——
Current Relay State: Z1 Terminal Load disabledsensor——
Current Relay State: Z2 Relay State disabledsensor——
Current Relay State: Z2 Terminal Load disabledsensor——
Power Source disabledsensor——
Remote Temperature Status disabledsensor——
System configuration: Aux Fan disabledsensor——
System configuration: Cool Stages disabledsensor——
System configuration: Fuel disabledsensor——
System configuration: HVAC Type disabledsensor——
System configuration: Heat Stages disabledsensor——
System configuration: Z1 Configuration disabledsensor——
System configuration: Z2 Configuration disabledsensor——
Diagnostics 1 Health and troubleshooting values, hidden from dashboards by default.
EntityTypeDevice classUnit
Battery levelsensorbattery%

Verified against Home Assistant 2026.8.3: its own Z-Wave discovery run over core's node dump of this device (ADC-T 3000) . Most of these are configuration parameters, which Home Assistant creates disabled and you enable as needed.

Hardware availability

Alarm.com hardware is sold and provisioned through authorized dealers, and the video, access control and business products also need the matching Alarm.com service plan on top of the hardware. The Z-Wave devices are the exception: they carry no service dependency once they are out of the panel’s network, and they turn up on the resale market at a fraction of dealer pricing.