Skip to main content
Selora Homes Selora Homes
Shelly logo
Shelly

Qubino Wave 1PM

A compact Z-Wave relay module with integrated power metering for a single 16A circuit. As a mains-powered device it repeats the Z-Wave mesh, extending range and reliability for the rest of your network.

Works on integrations
Protocols
Setup guides
Roles it can fill
Local over Z-Wave (Z-Wave JS), no cloud required. Single relay channel with precise power metering, 16A max load, neutral required; mains-powered so it repeats the Z-Wave 800-series mesh.

Entities in Home Assistant

59 entities via Z-Wave

Primary entities 32 What automations and dashboards use.
EntityTypeDevice classUnit
Alarm Levelbinary_sensor
Alarm Levelbinary_sensor
Alarm Typebinary_sensor
Alarm Typebinary_sensor
Hardware statusbinary_sensor
Hardware statusbinary_sensor
Heat sensor statusbinary_sensor
Heat sensor statusbinary_sensor
Over-current statusbinary_sensor
Over-current statusbinary_sensor
Hardware status disabledbutton
Hardware status disabledbutton
Heat sensor status disabledbutton
Heat sensor status disabledbutton
Over-current status disabledbutton
Over-current status disabledbutton
Cover (main)cover
Cover (main) disabledcover
Alarm Level disabledsensor
Alarm Level disabledsensor
Alarm Type disabledsensor
Alarm Type disabledsensor
Electric Consumption [W]sensorW
Electric Consumption [W]sensorW
Electric Consumption [kWh]sensorkWh
Electric Consumption [kWh]sensorkWh
Hardware statussensor
Hardware statussensor
Heat sensor statussensor
Heat sensor statussensor
Over-current statussensor
Over-current statussensor
Configuration 27 Settings exposed as entities, tunable from Home Assistant.
EntityTypeDevice classUnit
Identifybutton
Reset (Electric)button
Reset (Electric)button
Reset accumulated valuesbutton
Reset accumulated valuesbutton
Alarm conf. - CO disablednumber
Alarm conf. - Heat disablednumber
Alarm conf. - Smoke disablednumber
Alarm conf. - Water disablednumber
Delay Motor Stop disablednumber0.1 seconds
Down time disablednumber
Factory reset disablednumber
Indicator value disablednumber
Motor Moving Time disablednumberseconds
Motor Operation Detection disablednumberW
Next move delay disablednumber
Power Change Report Threshold disablednumber%
Power Consumption Measurement Delay disablednumber0.1 seconds
Slats turning time offset disablednumber
Up time disablednumber
Venetian Mode: Turning Time disablednumber0.01 seconds
Operating Mode disabledselect
SW1 Switch Type disabledselect
Shutter Calibration disabledselect
Swap Inputs disabledselect
Swap Outputs disabledselect
Venetian Mode: Restore Slats Position After Moving disabledselect

Verified against Home Assistant 2026.8.3: its own Z-Wave discovery run over core's node dump of this device (QNSH-001P10) . Most of these are configuration parameters, which Home Assistant creates disabled and you enable as needed.

Where to buy

Recipes using this device

No recipes reference this device yet.