Skip to main content
Selora Homes Selora Homes
Shelly
Shelly

Qubino Wave 1PM

A compact Z-Wave relay module with integrated power metering for a single 16A circuit. As a mains-powered device it repeats the Z-Wave mesh, extending range and reliability for the rest of your network.

Local over Z-Wave (Z-Wave JS), no cloud required. Single relay channel with precise power metering, 16A max load, neutral required; mains-powered so it repeats the Z-Wave 800-series mesh.
Works on integrations
Protocols
Roles it can fill

Entities in Home Assistant

59 entities via Z-Wave

Primary entities 32 What automations and dashboards use.
EntityTypeDevice classUnit
Alarm Levelbinary_sensor——
Alarm Levelbinary_sensor——
Alarm Typebinary_sensor——
Alarm Typebinary_sensor——
Hardware statusbinary_sensor——
Hardware statusbinary_sensor——
Heat sensor statusbinary_sensor——
Heat sensor statusbinary_sensor——
Over-current statusbinary_sensor——
Over-current statusbinary_sensor——
Hardware status disabledbutton——
Hardware status disabledbutton——
Heat sensor status disabledbutton——
Heat sensor status disabledbutton——
Over-current status disabledbutton——
Over-current status disabledbutton——
Cover (main)cover——
Cover (main) disabledcover——
Alarm Level disabledsensor——
Alarm Level disabledsensor——
Alarm Type disabledsensor——
Alarm Type disabledsensor——
Electric Consumption [W]sensor—W
Electric Consumption [W]sensor—W
Electric Consumption [kWh]sensor—kWh
Electric Consumption [kWh]sensor—kWh
Hardware statussensor——
Hardware statussensor——
Heat sensor statussensor——
Heat sensor statussensor——
Over-current statussensor——
Over-current statussensor——
Configuration 27 Settings exposed as entities, tunable from Home Assistant.
EntityTypeDevice classUnit
Identifybutton——
Reset (Electric)button——
Reset (Electric)button——
Reset accumulated valuesbutton——
Reset accumulated valuesbutton——
Alarm conf. - CO disablednumber——
Alarm conf. - Heat disablednumber——
Alarm conf. - Smoke disablednumber——
Alarm conf. - Water disablednumber——
Delay Motor Stop disablednumber—0.1 seconds
Down time disablednumber——
Factory reset disablednumber——
Indicator value disablednumber——
Motor Moving Time disablednumber—seconds
Motor Operation Detection disablednumber—W
Next move delay disablednumber——
Power Change Report Threshold disablednumber—%
Power Consumption Measurement Delay disablednumber—0.1 seconds
Slats turning time offset disablednumber——
Up time disablednumber——
Venetian Mode: Turning Time disablednumber—0.01 seconds
Operating Mode disabledselect——
SW1 Switch Type disabledselect——
Shutter Calibration disabledselect——
Swap Inputs disabledselect——
Swap Outputs disabledselect——
Venetian Mode: Restore Slats Position After Moving disabledselect——

Verified against Home Assistant 2026.8.3: its own Z-Wave discovery run over core's node dump of this device (QNSH-001P10) . Most of these are configuration parameters, which Home Assistant creates disabled and you enable as needed.